Products catalog

  • Digital clamp meter AC/DC

    Code: YT73092
  • Alternating voltage 0-600 V a.c.
    Direct voltage 0-600 V d.c.
    Alternating current 0-600 A
    Resistance 0-60 MΩ
    capability 0-20 mF
    Regularity 0-60 MHz
    Continuity test 0-120 Ω
    Conduction test yes
    Diode test yes
    Battery test yes
    Low-pass filter VFC yes
    TRUE RMS yes
    Data Hold yes
    Non-contact AC voltage detection NCV yes
    Dimensions 191x70x31 mm
    Material ABS
    Max. clamp gap 26 mm
    Max. diameter of the tested cable using the clamp 18 mm
    Display type LCD
    LED backlight yes
    Display range 5999
    Auto measurement range yes
    Sampling frequency 2.5-3 times per second
    Bell ring yes
    Auto power off 15 min
    Power supply battery cell type 2x1.5V; AAA
    Weight 0.19 kg

    Universal clamp meter YT-73092 with automatic range for most indications allows you to perform basic and advanced electrical measurements. The meter is equipped with measuring clamps, which allow you to measure the AC current in a single wire using the inductive method. The measurement is carried out without disconnecting the circuit or disconnecting it from the power source, and makes it possible to measure a much higher current than conventional electrical meters.

    Basic measurements:

    AC voltage measurement: A.C. 0-600 V, TRUE RMS + V.F.C. + lowZ
    DC voltage measurement: D.C. 0-600 V, LowZ
    alternating current measurement: A.C. 0-600 A, TRUE RMS + V.F.C.
    resistance measurement: 0-60 MΩ
    diode test: IF 1 mA, UR 2.3 V
    circuit continuity test: 0-120 Ω
    Additional measurements:

    AC voltage measurement in low impedance mode: A.C. 0-600 V
    DC voltage measurement in low impedance mode: D.C. 0-600 V
    non-contact AC voltage detection: NCV
    Measurement accuracies:

    Example of accuracy determination for AC current measurement. Calculation for the measurement result: 30 A

    The measurement accuracy of YT-73092 meter for this range is : ±(2.5%+10), resolution 0.01 A

    calculation of measurement error formula: (measurement result x 2.5%) + 10 x resolution
    calculation: (30 x 2.5%) + 10 x 0.01 = 0.75 + 0.1 = 0.8 A
    Actual result including measurement error for 30 A indication = 30 ± 0.85 A
    Result including measurement error for AC voltage measurement indication: 235 V = 235 ± 3.3 V
    result including measurement error for DC voltage measurement indication: 12 V = 12 ± 0.116 V
    A table with the resolution and accuracy for the measurement can be found in the user's manual.