Каталог товаров

  • Alternating voltage 0-600 V a.c.
    Direct voltage 0-600 V d.c.
    Alternating current 0-600 A
    Resistance 0-60 MΩ
    capability 0-60 mF
    Regularity 0-10 MHz
    Continuity test 0-50 Ω
    Conduction test yes
    Diode test yes
    Battery test yes
    Peak measured value preservation mode yes
    TRUE RMS yes
    Data Hold yes
    Non-contact AC voltage detection NCV yes
    Dimensions 172x64x32 mm
    Material ABS
    Max. clamp gap 25 mm
    Max. diameter of the tested cable using the clamp 25 mm
    Display type LCD
    LED backlight yes
    Display range 6000
    Auto measurement range yes
    Sampling frequency 3 times per second
    Bell ring yes
    Auto power off 15 min
    Power supply battery cell type 2x1.5V; AAA
    Weight 0.161 kg

    Universal clamp meter YT-73093 with automatic range selection for every measurement allows for basic and advanced measurements of electrical quantities. The meter is equipped with measurement clamps that allow for measurement of both direct and alternating current in a single wire using a built-in HALL sensor. The measurement can be done without disconnecting the circuit or disconnecting it from the power source and allows for measuring much higher current than conventional electrical meters. The measurement probe wires have silicone, flexible, and high-temperature resistant insulation.

    Basic measurements:

    measurement of alternating voltage: A.C. 0-600 V, TRUE RMS
    measurement of direct voltage: D.C. 0-600 V
    measurement of alternating current: A.C. 0-600 A, TRUE RMS
    measurement of direct current: D.C. 0-600 A
    measurement of resistance: 0-60 MΩ
    diode test: IF 5 mA, UR 3 V
    continuity test: 0-50 Ω
    Additional measurements:

    measurement of capacitor capacity: 0-60 mF
    measurement of frequency: 0-10 Mhz
    temperature measurement: -30 to 1000 °C
    non-contact detection of alternating voltage: NCV
    Measurement accuracy:

    Example of determining accuracy for the measurement of alternating current AC. Calculations for the measurement result: 30 A

    accuracy of the YT-73093 meter for this range is: ±(2.0%+30), resolution 0.01 A
    error calculation formula: (measurement result x 2%) + 30 x resolution
    calculations: (30 x 2%) + 30 x 0.01 = 0.6 + 0.3 = 0.90 A
    Actual result considering measurement error for indication of 30 A = 30 ± 0.90 A.

    result considering measurement error for indication of alternating voltage measurement: 235 V = 235 ± 4.175 V
    result considering measurement error for indication of direct voltage measurement: 12 V = 12 ± 0.09 V
    A table with resolution and accuracy for each measurement can be found in the user manual.